Every sensor, its last reading, its alerts

Follow cold-room temperature, trace an open door and assign the resulting alert to the person who will fix it.

IoT

Warehouse · Cold room 2

Cold room 2

Cold room 2

Temperature, °C
024681008:5508:5608:5708:5808:5909:0009:0109:0209:0309:0409:0509:0609:0709:0809:0909:10Upper limit 7.00Lower limit 2.00Door openDoor closed

Door opened 09:01:40 UTC · limit crossed 09:02:10 UTC · door closed 09:03:30 UTC · back under the limit 09:04:40 UTC

Show data as a table
Temperature, °C
Time (UTC)TemperatureLower limitUpper limit
08:55:004.172.007.00
08:55:104.142.007.00
08:55:204.172.007.00
08:55:304.152.007.00
08:55:404.242.007.00
08:55:504.152.007.00
08:56:004.242.007.00
08:56:104.142.007.00
08:56:204.232.007.00
08:56:304.202.007.00
08:56:404.232.007.00
08:56:504.212.007.00
08:57:004.152.007.00
08:57:104.212.007.00
08:57:204.172.007.00
08:57:304.172.007.00
08:57:404.142.007.00
08:57:504.212.007.00
08:58:004.142.007.00
08:58:104.242.007.00
08:58:204.182.007.00
08:58:304.142.007.00
08:58:404.212.007.00
08:58:504.262.007.00
08:59:004.232.007.00
08:59:104.172.007.00
08:59:204.242.007.00
08:59:304.182.007.00
08:59:404.242.007.00
08:59:504.202.007.00
09:00:004.182.007.00
09:00:104.172.007.00
09:00:204.242.007.00
09:00:304.212.007.00
09:00:404.142.007.00
09:00:504.222.007.00
09:01:004.142.007.00
09:01:104.242.007.00
09:01:204.172.007.00
09:01:304.232.007.00
09:01:404.352.007.00
09:01:504.902.007.00
09:02:006.312.007.00
09:02:107.122.007.00
09:02:207.582.007.00
09:02:307.912.007.00
09:02:408.122.007.00
09:02:508.272.007.00
09:03:008.382.007.00
09:03:108.472.007.00
09:03:208.532.007.00
09:03:308.582.007.00
09:03:408.522.007.00
09:03:508.392.007.00
09:04:008.122.007.00
09:04:107.782.007.00
09:04:207.452.007.00
09:04:307.142.007.00
09:04:406.882.007.00
09:04:506.522.007.00
09:05:006.172.007.00
09:05:106.142.007.00
09:05:206.132.007.00
09:05:306.052.007.00
09:05:406.052.007.00
09:05:506.002.007.00
09:06:005.992.007.00
09:06:105.952.007.00
09:06:205.932.007.00
09:06:305.902.007.00
09:06:405.882.007.00
09:06:505.842.007.00
09:07:005.802.007.00
09:07:105.792.007.00
09:07:205.752.007.00
09:07:305.742.007.00
09:07:405.712.007.00
09:07:505.672.007.00
09:08:005.662.007.00
09:08:105.652.007.00
09:08:205.612.007.00
09:08:305.572.007.00
09:08:405.582.007.00
09:08:505.562.007.00
09:09:005.532.007.00
09:09:105.502.007.00
09:09:205.492.007.00
09:09:305.462.007.00
09:09:405.432.007.00
09:09:505.422.007.00
09:10:005.392.007.00
09:10:105.392.007.00
09:10:205.362.007.00
09:10:305.322.007.00
09:10:405.322.007.00
09:10:505.302.007.00

6 of 6 rows

Cold room 2
PathValueUnitQualitySource time (UTC)
cold-room-2/temperature5.30°C09:10:50
cold-room-2/door0boolean09:03:30
cold-room-2/humidity61.2%08:12:40
cold-room-2/setpoint4.00°C08:30:00
cold-room-2/battery68%09:10:50
cold-room-2/signal-74dBm09:10:50

Press Enter to open the record.

From a reading over the limit to a work order

  1. The rule fires

    Good-quality readings stay above the configured threshold for the full rule duration before the alert records its opening time.

    Show it: The rule fires
  2. Acknowledge and assign

    Acknowledge the alert to record that someone has taken responsibility, then assign the person who will inspect the cold-room door.

    Show it: Acknowledge and assign
  3. Create the work order

    Create the work order from the assigned alert; its identifier stays on the alert, so a repeated request does not create another task.

    Show it: Create the work order

The link drops, the readings wait and arrive in order

The gateway keeps each reading with its source time. After reconnection, the oldest reading leaves first.

since 09:11:00 UTC · 12 readings held

Readings held at the gateway
SequenceSource time (UTC)PathValueDelivery order
28909:11:00cold-room-1/temperature3.84 °C1 · oldest
29009:11:00cold-room-2/temperature5.26 °C2
29109:11:00cold-room-3/temperature4.37 °C3
29209:11:10cold-room-1/temperature3.93 °C4
29309:11:10cold-room-2/temperature5.27 °C5
29409:11:10cold-room-3/temperature4.41 °C6

From the sensor to the technician’s phone

Step 1 of 6

  1. Sensor, outside the company
  2. Gateway, connector
  3. Rules, product
  4. Alert, product
  5. ERP, product
  6. Mobile Apps, product

Temperature over the limit

  1. Sensor, outside the company

    Read the temperature

    The sensor reports a value with its source time.

    Reading
    reading-131
    Value
    7.12 °C
    Source time
    09:02:10 UTC
  2. Gateway, connector

    Keep the source time

    The gateway forwards the reading without changing its timestamp.

    Reading
    reading-131
    Value
    7.12 °C
    Source time
    09:02:10 UTC
  3. Rules, product

    Check the threshold

    The readings stay above 7.00 °C for 60 seconds, so the alert opens.

    Reading
    reading-149
    Value
    8.47 °C
    Source time
    09:03:10 UTC
    Alert
    alert-1 · opened 09:03:10 UTC
  4. Alert, product

    Acknowledge and assign the alert

    Mihai Stan takes responsibility for the alert.

    Alert
    alert-1 · acknowledged 09:11:30 UTC
    Assignee
    Mihai Stan
  5. ERP, product

    Link the work order

    The alert keeps the identifier of its ERP work order.

    Alert
    alert-1
    Assignee
    Mihai Stan
    Work order
    WO-1042
  6. Mobile Apps, product

    Open the assigned task

    The technician follows the assigned work order on the phone.

    Assignee
    Mihai Stan
    Work order
    WO-1042

Uplink cut, buffered, delivered in order

  1. Sensor, outside the company

    Keep reading

    The sensor keeps producing readings with their source times.

    Reading
    reading-289
    Value
    3.84 °C
    Source time
    09:11:00 UTC
  2. Gateway, connector

    Hold the readings

    The uplink is down, so the gateway keeps the readings in sequence.

    Reading
    reading-300
    Value
    4.40 °C
    Source time
    09:11:30 UTC
    Held at the gateway
    12, oldest 09:11:00 UTC
  3. Gateway, connector

    Restore the uplink

    The link returns and every held reading is still there, in order.

    Held at the gateway
    12, oldest 09:11:00 UTC
  4. Rules, product

    Deliver the oldest first

    The reading with the oldest source time reaches the rules first.

    Reading
    reading-289
    Value
    3.84 °C
    Source time
    09:11:00 UTC
    Held at the gateway
    11
  5. Rules, product

    Finish the ordered delivery

    Every held reading has arrived with its original source time.

    Reading
    reading-300
    Value
    4.40 °C
    Source time
    09:11:30 UTC
    Held at the gateway
    0

What each step writes

Temperature over the limit
StepRecord created or changed
1 Read the temperatureReading reading-131: value 7.12 °C, source time 09:02:10 UTC, quality good.
2 Keep the source timeReading reading-131 arrives with sequence 131; its source time stays 09:02:10 UTC.
3 Check the thresholdAlert alert-1: state open, opened 09:03:10 UTC by reading reading-149, rule rule-1.
4 Acknowledge and assign the alertAlert alert-1: acknowledged 09:11:30 UTC, assignee Mihai Stan from 09:12:00 UTC.
5 Link the work orderAlert alert-1: work order WO-1042 linked 09:12:30 UTC.
6 Open the assigned taskWork order WO-1042: assignee Mihai Stan.
Uplink cut, buffered, delivered in order
StepRecord created or changed
1 Keep readingReadings reading-289 to reading-300 are produced with source times 09:11:00 to 09:11:30 UTC.
2 Hold the readingsGateway buffer: 12 readings held, sequence 289 to 300, uplink down since 09:11:00 UTC.
3 Restore the uplinkGateway: uplink up, 12 readings still held, none lost.
4 Deliver the oldest firstReading reading-289 delivered first; 11 readings held; source time unchanged 09:11:00 UTC.
5 Finish the ordered deliveryReading reading-300 delivered last; 0 readings held; 12 delivered in sequence.

What a reading carries

Value
FieldValueMeaning
pathcold-room-2/temperatureIdentifies the measurement inside the authenticated company; use the same path when requesting its feed, history or threshold rule.
value8.47The measurement is a decimal string. Keep its precision when storing it; convert to a number only for calculations or a formatted display.
unit°CThe unit belongs to the tag and accompanies every reading, so the temperature threshold and the recorded value can be compared in the same unit.
qualitygoodThe acquisition is usable. Include this reading in the minute aggregate and evaluate it against the configured temperature rule.
qualitystaleThe last known value is retained with its original source time. Check the source connection before treating it as a current measurement.
qualitybadAcquisition did not produce a usable measurement. Exclude it from the aggregate and inspect the device rather than substituting a zero.
sourceTime2026-11-20T09:03:10ZThe source timestamp is expressed in UTC. Buffering and reconnection preserve this time; arrival at the gateway does not replace it.

Firmware updated in stages, stopped when needed

  • Start with 5%

    The first 2 devices report before the rollout continues; a device that fails stops it and its result stays in the history.

  • Continue to 25%

    10 devices in all report next; Stop freezes the stage, Resume continues it and a failed stage can be retried.

  • Reach 100%

    The last stage covers all 38 devices that can take the update; a stopped or failed stage never moves the rollout forward.

Show it: Alerts and updates

Read a value from your code

curl

curl "$RDC_BASE_URL/iot/v1/devices/device-12/tags?path=cold-room-2%2Ftemperature" \
  -H "Authorization: Bearer $RDC_TOKEN"

Response200 OK

{
  "items": [
    {
      "id": "tag-cold-room-2-temperature",
      "sequence": 287,
      "path": "cold-room-2/temperature",
      "value": "5.30",
      "unit": "°C",
      "quality": "good",
      "sourceTime": "2026-11-20T09:10:50Z"
    }
  ],
  "nextCursor": null
}

Questions about devices and alerts

Which connections can a device use?

MQTT, LoRaWAN, NB-IoT, LTE-M, Modbus, OPC UA, Wi-Fi and Ethernet are described in the connectivity guides.

Does the temperature band set a safety rule?

No. The band is a setting for this cold room. Set the threshold and duration to match the equipment and your operating procedures.

What happens when the uplink drops?

The gateway holds the readings with their original source times and delivers them in sequence when the link returns.

Can an alert open a work order?

Assign the alert first, then create its ERP work order. The alert keeps the work-order identifier.

Can a firmware rollout be stopped?

Yes. Stop a running update and resume it later. Each stage keeps its device results, including failed attempts.

How do I receive readings in my application?

Read the tag snapshot or follow the measurement feed. Subscribe to signed events for alerts and verify each delivery before accepting it.

Proposal for IoT

Tell us which sites, sensors and maintenance tasks you need to connect.

Request a proposal