Every sensor, its last reading, its alerts
Follow cold-room temperature, trace an open door and assign the resulting alert to the person who will fix it.
IoT
Cold room 2
Door opened 09:01:40 UTC · limit crossed 09:02:10 UTC · door closed 09:03:30 UTC · back under the limit 09:04:40 UTC
Show data as a table
| Time (UTC) | Temperature | Lower limit | Upper limit |
|---|---|---|---|
| 08:55:00 | 4.17 | 2.00 | 7.00 |
| 08:55:10 | 4.14 | 2.00 | 7.00 |
| 08:55:20 | 4.17 | 2.00 | 7.00 |
| 08:55:30 | 4.15 | 2.00 | 7.00 |
| 08:55:40 | 4.24 | 2.00 | 7.00 |
| 08:55:50 | 4.15 | 2.00 | 7.00 |
| 08:56:00 | 4.24 | 2.00 | 7.00 |
| 08:56:10 | 4.14 | 2.00 | 7.00 |
| 08:56:20 | 4.23 | 2.00 | 7.00 |
| 08:56:30 | 4.20 | 2.00 | 7.00 |
| 08:56:40 | 4.23 | 2.00 | 7.00 |
| 08:56:50 | 4.21 | 2.00 | 7.00 |
| 08:57:00 | 4.15 | 2.00 | 7.00 |
| 08:57:10 | 4.21 | 2.00 | 7.00 |
| 08:57:20 | 4.17 | 2.00 | 7.00 |
| 08:57:30 | 4.17 | 2.00 | 7.00 |
| 08:57:40 | 4.14 | 2.00 | 7.00 |
| 08:57:50 | 4.21 | 2.00 | 7.00 |
| 08:58:00 | 4.14 | 2.00 | 7.00 |
| 08:58:10 | 4.24 | 2.00 | 7.00 |
| 08:58:20 | 4.18 | 2.00 | 7.00 |
| 08:58:30 | 4.14 | 2.00 | 7.00 |
| 08:58:40 | 4.21 | 2.00 | 7.00 |
| 08:58:50 | 4.26 | 2.00 | 7.00 |
| 08:59:00 | 4.23 | 2.00 | 7.00 |
| 08:59:10 | 4.17 | 2.00 | 7.00 |
| 08:59:20 | 4.24 | 2.00 | 7.00 |
| 08:59:30 | 4.18 | 2.00 | 7.00 |
| 08:59:40 | 4.24 | 2.00 | 7.00 |
| 08:59:50 | 4.20 | 2.00 | 7.00 |
| 09:00:00 | 4.18 | 2.00 | 7.00 |
| 09:00:10 | 4.17 | 2.00 | 7.00 |
| 09:00:20 | 4.24 | 2.00 | 7.00 |
| 09:00:30 | 4.21 | 2.00 | 7.00 |
| 09:00:40 | 4.14 | 2.00 | 7.00 |
| 09:00:50 | 4.22 | 2.00 | 7.00 |
| 09:01:00 | 4.14 | 2.00 | 7.00 |
| 09:01:10 | 4.24 | 2.00 | 7.00 |
| 09:01:20 | 4.17 | 2.00 | 7.00 |
| 09:01:30 | 4.23 | 2.00 | 7.00 |
| 09:01:40 | 4.35 | 2.00 | 7.00 |
| 09:01:50 | 4.90 | 2.00 | 7.00 |
| 09:02:00 | 6.31 | 2.00 | 7.00 |
| 09:02:10 | 7.12 | 2.00 | 7.00 |
| 09:02:20 | 7.58 | 2.00 | 7.00 |
| 09:02:30 | 7.91 | 2.00 | 7.00 |
| 09:02:40 | 8.12 | 2.00 | 7.00 |
| 09:02:50 | 8.27 | 2.00 | 7.00 |
| 09:03:00 | 8.38 | 2.00 | 7.00 |
| 09:03:10 | 8.47 | 2.00 | 7.00 |
| 09:03:20 | 8.53 | 2.00 | 7.00 |
| 09:03:30 | 8.58 | 2.00 | 7.00 |
| 09:03:40 | 8.52 | 2.00 | 7.00 |
| 09:03:50 | 8.39 | 2.00 | 7.00 |
| 09:04:00 | 8.12 | 2.00 | 7.00 |
| 09:04:10 | 7.78 | 2.00 | 7.00 |
| 09:04:20 | 7.45 | 2.00 | 7.00 |
| 09:04:30 | 7.14 | 2.00 | 7.00 |
| 09:04:40 | 6.88 | 2.00 | 7.00 |
| 09:04:50 | 6.52 | 2.00 | 7.00 |
| 09:05:00 | 6.17 | 2.00 | 7.00 |
| 09:05:10 | 6.14 | 2.00 | 7.00 |
| 09:05:20 | 6.13 | 2.00 | 7.00 |
| 09:05:30 | 6.05 | 2.00 | 7.00 |
| 09:05:40 | 6.05 | 2.00 | 7.00 |
| 09:05:50 | 6.00 | 2.00 | 7.00 |
| 09:06:00 | 5.99 | 2.00 | 7.00 |
| 09:06:10 | 5.95 | 2.00 | 7.00 |
| 09:06:20 | 5.93 | 2.00 | 7.00 |
| 09:06:30 | 5.90 | 2.00 | 7.00 |
| 09:06:40 | 5.88 | 2.00 | 7.00 |
| 09:06:50 | 5.84 | 2.00 | 7.00 |
| 09:07:00 | 5.80 | 2.00 | 7.00 |
| 09:07:10 | 5.79 | 2.00 | 7.00 |
| 09:07:20 | 5.75 | 2.00 | 7.00 |
| 09:07:30 | 5.74 | 2.00 | 7.00 |
| 09:07:40 | 5.71 | 2.00 | 7.00 |
| 09:07:50 | 5.67 | 2.00 | 7.00 |
| 09:08:00 | 5.66 | 2.00 | 7.00 |
| 09:08:10 | 5.65 | 2.00 | 7.00 |
| 09:08:20 | 5.61 | 2.00 | 7.00 |
| 09:08:30 | 5.57 | 2.00 | 7.00 |
| 09:08:40 | 5.58 | 2.00 | 7.00 |
| 09:08:50 | 5.56 | 2.00 | 7.00 |
| 09:09:00 | 5.53 | 2.00 | 7.00 |
| 09:09:10 | 5.50 | 2.00 | 7.00 |
| 09:09:20 | 5.49 | 2.00 | 7.00 |
| 09:09:30 | 5.46 | 2.00 | 7.00 |
| 09:09:40 | 5.43 | 2.00 | 7.00 |
| 09:09:50 | 5.42 | 2.00 | 7.00 |
| 09:10:00 | 5.39 | 2.00 | 7.00 |
| 09:10:10 | 5.39 | 2.00 | 7.00 |
| 09:10:20 | 5.36 | 2.00 | 7.00 |
| 09:10:30 | 5.32 | 2.00 | 7.00 |
| 09:10:40 | 5.32 | 2.00 | 7.00 |
| 09:10:50 | 5.30 | 2.00 | 7.00 |
Sites and devices
Nothing is waiting. Each reading is delivered as it arrives.
Sites and devices
| Device | Connection | Last heard | Firmware | Signal | Battery | Alerts |
|---|---|---|---|---|---|---|
| Warehouse gatewayWarehouse | Ethernet | 09:10:58 UTC | 2.4.1 | — | — | 0 |
| Compressor controllerWarehouse | OPC UA | 09:10:55 UTC | 2.4.1 | — | — | 0 |
| Energy meterWarehouse | Modbus | 09:10:30 UTC | 2.4.1 | — | — | 0 |
| Air temperature probeCold room 2 | LoRaWAN | 09:10:50 UTC | 2.4.1 | -74 dBm | 68% | 1 |
| Product temperature probeCold room 2 | LoRaWAN | 09:10:50 UTC | 2.4.1 | -81 dBm | 57% | 0 |
| Door sensorCold room 2 | LoRaWAN | 09:10:40 UTC | 2.4.1 | -88 dBm | 46% | 0 |
| Humidity probeCold room 2 | LoRaWAN | 08:12:40 UTC | 2.4.1 | -61 dBm | 4% | 0 |
| Evaporator controllerCold room 2 | Modbus | 09:10:55 UTC | 2.4.1 | — | — | 0 |
| Defrost controllerCold room 2 | Modbus | 09:10:55 UTC | 2.4.1 | — | — | 0 |
| Fan controllerCold room 2 | MQTT | 09:10:45 UTC | 2.4.1 | — | — | 0 |
| Leak detectorCold room 2 | LoRaWAN | 09:10:30 UTC | 2.4.1 | -89 dBm | 95% | 0 |
Alerts and updates
Temperature above 7.00 °C for 60 s
alert-1
- Rule
- rule-1 · cold-room-2/temperature
- Opened by reading
- reading-149 · 8.47 °C · 09:03:10 UTC
- First reading above the limit
- reading-131 · 7.12 °C · 09:02:10 UTC
- Assignee
- Unassigned
- Work order
- —
Alert history
- Opened by rule-1
Firmware 2.4.2 · 38 devices
Left out: 2 offline devices
| Stage | Devices | Attempt | Succeeded | Failed | Status |
|---|---|---|---|---|---|
| 5% | 2 | — | — | — | |
| 25% | 10 | — | — | — | |
| 100% | 38 | — | — | — |
From a reading over the limit to a work order
-
The rule fires
Good-quality readings stay above the configured threshold for the full rule duration before the alert records its opening time.
Show it: The rule fires -
Acknowledge and assign
Acknowledge the alert to record that someone has taken responsibility, then assign the person who will inspect the cold-room door.
Show it: Acknowledge and assign -
Create the work order
Create the work order from the assigned alert; its identifier stays on the alert, so a repeated request does not create another task.
Show it: Create the work order
The link drops, the readings wait and arrive in order
The gateway keeps each reading with its source time. After reconnection, the oldest reading leaves first.
since 09:11:00 UTC · 12 readings held
| Sequence | Source time (UTC) | Path | Value | Delivery order |
|---|---|---|---|---|
| 289 | 09:11:00 | cold-room-1/temperature | 3.84 °C | 1 · oldest |
| 290 | 09:11:00 | cold-room-2/temperature | 5.26 °C | 2 |
| 291 | 09:11:00 | cold-room-3/temperature | 4.37 °C | 3 |
| 292 | 09:11:10 | cold-room-1/temperature | 3.93 °C | 4 |
| 293 | 09:11:10 | cold-room-2/temperature | 5.27 °C | 5 |
| 294 | 09:11:10 | cold-room-3/temperature | 4.41 °C | 6 |
From the sensor to the technician’s phone
- Sensor, outside the company
- Gateway, connector
- Rules, product
- Alert, product
- ERP, product
- Mobile Apps, product
Temperature over the limit
Sensor, outside the company
Read the temperature
The sensor reports a value with its source time.
- Reading
- reading-131
- Value
- 7.12 °C
- Source time
- 09:02:10 UTC
Gateway, connector
Keep the source time
The gateway forwards the reading without changing its timestamp.
- Reading
- reading-131
- Value
- 7.12 °C
- Source time
- 09:02:10 UTC
Rules, product
Check the threshold
The readings stay above 7.00 °C for 60 seconds, so the alert opens.
- Reading
- reading-149
- Value
- 8.47 °C
- Source time
- 09:03:10 UTC
- Alert
- alert-1 · opened 09:03:10 UTC
Alert, product
Acknowledge and assign the alert
Mihai Stan takes responsibility for the alert.
- Alert
- alert-1 · acknowledged 09:11:30 UTC
- Assignee
- Mihai Stan
ERP, product
Link the work order
The alert keeps the identifier of its ERP work order.
- Alert
- alert-1
- Assignee
- Mihai Stan
- Work order
- WO-1042
Mobile Apps, product
Open the assigned task
The technician follows the assigned work order on the phone.
- Assignee
- Mihai Stan
- Work order
- WO-1042
Uplink cut, buffered, delivered in order
Sensor, outside the company
Keep reading
The sensor keeps producing readings with their source times.
- Reading
- reading-289
- Value
- 3.84 °C
- Source time
- 09:11:00 UTC
Gateway, connector
Hold the readings
The uplink is down, so the gateway keeps the readings in sequence.
- Reading
- reading-300
- Value
- 4.40 °C
- Source time
- 09:11:30 UTC
- Held at the gateway
- 12, oldest 09:11:00 UTC
Gateway, connector
Restore the uplink
The link returns and every held reading is still there, in order.
- Held at the gateway
- 12, oldest 09:11:00 UTC
Rules, product
Deliver the oldest first
The reading with the oldest source time reaches the rules first.
- Reading
- reading-289
- Value
- 3.84 °C
- Source time
- 09:11:00 UTC
- Held at the gateway
- 11
Rules, product
Finish the ordered delivery
Every held reading has arrived with its original source time.
- Reading
- reading-300
- Value
- 4.40 °C
- Source time
- 09:11:30 UTC
- Held at the gateway
- 0
What each step writes
| Step | Record created or changed |
|---|---|
| 1 Read the temperature | Reading reading-131: value 7.12 °C, source time 09:02:10 UTC, quality good. |
| 2 Keep the source time | Reading reading-131 arrives with sequence 131; its source time stays 09:02:10 UTC. |
| 3 Check the threshold | Alert alert-1: state open, opened 09:03:10 UTC by reading reading-149, rule rule-1. |
| 4 Acknowledge and assign the alert | Alert alert-1: acknowledged 09:11:30 UTC, assignee Mihai Stan from 09:12:00 UTC. |
| 5 Link the work order | Alert alert-1: work order WO-1042 linked 09:12:30 UTC. |
| 6 Open the assigned task | Work order WO-1042: assignee Mihai Stan. |
| Step | Record created or changed |
|---|---|
| 1 Keep reading | Readings reading-289 to reading-300 are produced with source times 09:11:00 to 09:11:30 UTC. |
| 2 Hold the readings | Gateway buffer: 12 readings held, sequence 289 to 300, uplink down since 09:11:00 UTC. |
| 3 Restore the uplink | Gateway: uplink up, 12 readings still held, none lost. |
| 4 Deliver the oldest first | Reading reading-289 delivered first; 11 readings held; source time unchanged 09:11:00 UTC. |
| 5 Finish the ordered delivery | Reading reading-300 delivered last; 0 readings held; 12 delivered in sequence. |
What a reading carries
| Field | Value | Meaning |
|---|---|---|
| path | cold-room-2/temperature | Identifies the measurement inside the authenticated company; use the same path when requesting its feed, history or threshold rule. |
| value | 8.47 | The measurement is a decimal string. Keep its precision when storing it; convert to a number only for calculations or a formatted display. |
| unit | °C | The unit belongs to the tag and accompanies every reading, so the temperature threshold and the recorded value can be compared in the same unit. |
| quality | good | The acquisition is usable. Include this reading in the minute aggregate and evaluate it against the configured temperature rule. |
| quality | stale | The last known value is retained with its original source time. Check the source connection before treating it as a current measurement. |
| quality | bad | Acquisition did not produce a usable measurement. Exclude it from the aggregate and inspect the device rather than substituting a zero. |
| sourceTime | 2026-11-20T09:03:10Z | The source timestamp is expressed in UTC. Buffering and reconnection preserve this time; arrival at the gateway does not replace it. |
Firmware updated in stages, stopped when needed
-
Start with 5%
The first 2 devices report before the rollout continues; a device that fails stops it and its result stays in the history.
-
Continue to 25%
10 devices in all report next; Stop freezes the stage, Resume continues it and a failed stage can be retried.
-
Reach 100%
The last stage covers all 38 devices that can take the update; a stopped or failed stage never moves the rollout forward.
Read a value from your code
curl "$RDC_BASE_URL/iot/v1/devices/device-12/tags?path=cold-room-2%2Ftemperature" \
-H "Authorization: Bearer $RDC_TOKEN"const response = await fetch(`${process.env.RDC_BASE_URL}/iot/v1/devices/device-12/tags?path=cold-room-2%2Ftemperature`, {
method: 'GET',
headers: {
Authorization: `Bearer ${process.env.RDC_TOKEN}`,
},
});
const result = await response.json();import os
import requests
response = requests.request(
'GET',
f'{os.environ["RDC_BASE_URL"]}/iot/v1/devices/device-12/tags?path=cold-room-2%2Ftemperature',
headers={
'Authorization': f'Bearer {os.environ["RDC_TOKEN"]}',
},
)
result = response.json()<?php
$curl = curl_init(getenv('RDC_BASE_URL') . '/iot/v1/devices/device-12/tags?path=cold-room-2%2Ftemperature');
curl_setopt_array($curl, [
CURLOPT_CUSTOMREQUEST => 'GET',
CURLOPT_RETURNTRANSFER => true,
CURLOPT_HTTPHEADER => [
'Authorization: Bearer ' . getenv('RDC_TOKEN'),
],
]);
$result = json_decode(curl_exec($curl), true);
curl_close($curl);using System.Net.Http.Headers;
var client = new HttpClient();
var request = new HttpRequestMessage(HttpMethod.Get, $"{Environment.GetEnvironmentVariable("RDC_BASE_URL")}/iot/v1/devices/device-12/tags?path=cold-room-2%2Ftemperature");
request.Headers.Authorization = new AuthenticationHeaderValue("Bearer", Environment.GetEnvironmentVariable("RDC_TOKEN"));
var response = await client.SendAsync(request);
var result = await response.Content.ReadAsStringAsync(); Response200 OK
{
"items": [
{
"id": "tag-cold-room-2-temperature",
"sequence": 287,
"path": "cold-room-2/temperature",
"value": "5.30",
"unit": "°C",
"quality": "good",
"sourceTime": "2026-11-20T09:10:50Z"
}
],
"nextCursor": null
} Questions about devices and alerts
Which connections can a device use?
MQTT, LoRaWAN, NB-IoT, LTE-M, Modbus, OPC UA, Wi-Fi and Ethernet are described in the connectivity guides.
Does the temperature band set a safety rule?
No. The band is a setting for this cold room. Set the threshold and duration to match the equipment and your operating procedures.
What happens when the uplink drops?
The gateway holds the readings with their original source times and delivers them in sequence when the link returns.
Can an alert open a work order?
Assign the alert first, then create its ERP work order. The alert keeps the work-order identifier.
Can a firmware rollout be stopped?
Yes. Stop a running update and resume it later. Each stage keeps its device results, including failed attempts.
How do I receive readings in my application?
Read the tag snapshot or follow the measurement feed. Subscribe to signed events for alerts and verify each delivery before accepting it.
Proposal for IoT
Tell us which sites, sensors and maintenance tasks you need to connect.